    Listeria monocytogenes is a pathogenic bacterium, therefore, it is essential for food safety monitoring to establish a rapid and specific detecting method. In this study, immunomagnetic beads and selective medium were combined to detect Listeria monocytogenes at different concentrations (101?105 CFU/mL). Other three types of Listeria spp., Staphylococcus aureus and Vibrio parahaemolyticus were also detected to conduct the cross-reaction analysis. Meanwhile, contaminated milk samples were prepared to explore the limit of detection of immunomagnetic beads combining with selective medium. Results showed that Listeria monocytogenes with the concentration of 103 CFU/mL and above was successfully detected. Milk samples were detected within 6 hours, with a detection limit of 0.7 CFU/mL. The method developed is capable of detecting milk samples within 30 h, which is 38 h faster compared with national standard method with the same sensitivity.