Application of reverse phase C18 tip in pretreatment of small amount complex proteomic samples
Author:
Affiliation:

Clc Number:

Fund Project:

National Basic Research Program of China (973 Program) (Nos. 2013CB530805, 2014CBA02005), Key Basic Research Program of the Ministry of Science and Technology of China (No. 2013FY114100).

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    To develop a timesaving and easy operating Reverse Phase (RP) chromatography method, we adopted Thermo Pierce? RP C18 Tip to separate small amount hippocampus peptide mixtures and to compare with high performance liquid chromatography (HPLC). According to the separation performance of 4 ACN gradient optimization methods, we determined the best ACN concentration gradient. The results showed that, the experiment took only 10 min by separating with eight ACN concentration gradient, which accounted 1/4 for HPLC. But as for the identified proteins, RP C18 Tip accounted 85.5% for HPLC. ACN gradient of 5%, 15%, 20% and 90% had best repeatability (P=0.429) and result for separating 30 μg peptides. This method is easy to operate, timesaving and has low cost. It could be used into pretreatment of small amount complex proteomic samples.

    Reference
    Related
    Cited by
Get Citation

王丹琪,孙伟,邹丽莉,王瞾. 反相C18固相萃取小柱用于蛋白质组分析中少量样品预处理[J]. Chinese Journal of Biotechnology, 2015, 31(11): 1643-1650

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:December 15,2014
  • Revised:
  • Adopted:
  • Online: October 29,2015
  • Published:
Article QR Code