一种定量检测人血清高敏C反应蛋白的化学发光免疫方法
DOI:
CSTR:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:

国家高技术研究发展计划 (863计划) (No. 2006AA020905),福建省医学创新课题 (No. 2009-CXB-55) 资助。


Chemiluminescent immunoassay for high-sensitivity C-reactive protein
Author:
Affiliation:

Fund Project:

National High Technology Research and Development Program (863 Program) (No. 2006AA020905), Fujian Medical Innovation Program (No. 2009-CXB-55).

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    旨在建立一种可定量检测人血清高敏CRP的化学发光检测方法 (High-sensitivity C-reactive protein quantifiable chemiluminescent immunoassay,hs-CRP CLIA)。首先利用亲和层析和离子交换层析技术从肝硬化病人腹水中纯化出高纯度的天然CRP作为免疫原制备了22株CRP单克隆抗体 (单抗),其中13株单抗在磷酸胆碱配体捕获ELISA中呈阳性,然后利用方正滴定法筛选出单抗10C5和10C11建立了hs-CRP CLIA。试剂盒评估结果显示:该方法对血清中干扰物质IgG、血红蛋白、甘油三酯等无非特异性反应;该方法检测灵敏度高,在0.04~20.38 mg/L范围内定量检测人血清CRP标准品呈良好线性关系 (R2>0.993);该方法准确性高、可重复性好,平均回收率为99%,批内差为4.2%~5.8%,批间差为9.0%~11.5%;该方法与进口商品化高敏CRP ELISA试剂盒平行比较检测90份血清标本,结果显示两者有良好的可比性 (r=0.968)。综上,建立的hs-CRP CLIA是一种准确、可靠、可定量的高灵敏C反应蛋白检测方法,该方法的临床应用,有利于改善我国心脏病风险评估及肠炎性疾病预后判断。

    Abstract:

    We developed a high-sensitivity C-reactive protein quantifiable chemiluminescent immunoassay (hs-CRP CLIA). The high-purity native CRP was purified from hepatic cirrhosis patient ascetic fluid by affinity and ion exchange chromatography and used as an immunogen to develop the monoclonal antibodies (mAbs) against CRP. Twenty-two mAbs were identified reactive with CRP in ELISA and 13 of them were reactive in the phosphorycholine ligand capture ELISA. The mAbs 10C5 and 10C11 were selected to develop the hs-CRP CLIA. The linearity and performance of the hs-CRP CLIA was characterized. It was showed not reactive when testing against other serum materials (IgG, hemoglobin and triglyceride). The reliable correlation (R2 > 0.993) was obtained between testing value (RLU/S) and the concentration of human serum CRP calibrator. The linearity fell in the range of 0.04?20.38 mg/L. The assay has good accuracy and reproducibility, the mean recovery was 99% and the precision of the intra- and inter assay was CVs (4.2%?5.8%) and (9.0%?11.5%), respectively. In testing of 90 human sera, this assay performed well and correlated comparably with a commercial hs-CRP ELISA kit. Thus, hs-CRP CLIA is an accurate, reliable, quantifiable assay for detection of high-sensitive C-reactive protein in serum, it may be useful to improve the risk assessment of cardiovascular disease and the prognosis of inflammatory bowel disease.

    参考文献
    相似文献
    引证文献
引用本文

刘平果,李国强,陈毅歆,罗海峰,黄德党,王颖彬,葛胜祥,张军,夏宁邵. 一种定量检测人血清高敏C反应蛋白的化学发光免疫方法[J]. 生物工程学报, 2010, 26(8): 1150-1156

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2010-02-03
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期:
  • 出版日期:
文章二维码
您是第位访问者
生物工程学报 ® 2024 版权所有

通信地址:中国科学院微生物研究所    邮编:100101

电话:010-64807509   E-mail:cjb@im.ac.cn