Rapid generation of double-layer emulsion droplets based on microfluidic chip
Author:
Affiliation:

Clc Number:

Fund Project:

Novo Nordisk-Chinese Academy of Sciences (NN-CAS) Research Fund (No. NNCAS-2015-6), Instrument Developing Project of the Chinese Academy of Sciences (No. YJKYYQ20170023), Tianjin Synthetic Biotechnology Innovation Capacity Improvement Project (No. TSBICIP-PTJS-003).

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    In vitro compartmentalization (IVC) links genotype and phenotype by compartmentalizing individual genes (including expression system) or cells into a micro-droplet reaction region. Combined with fluorescence-activated cell sorting (FACS), it can detect and separate single droplets in ultra-high throughput. IVC-FACS screening method has been widely used in protein engineering, enzyme directed evolution, etc. However, it is difficult to control the homogeneity of droplet size by mechanical dispersion method in previous studies, which seriously affects the quantitative detection of droplets and reduces the efficiency and accuracy of this screening method. With the rapid development of microfluidic chip manufacturing technology, the microfluidic chip-based methods for droplet generation are becoming more efficient and controllable. In this study, firstly, the water-in-oil (W/O) single-layer droplet generation chip was used to prepare single-layer monodisperse W1/O droplets at a high generation frequency, and then the W1/O droplets were reinjected into water-in-oil-in-water (W/O/W) double-layer droplet generation chip to prepare uniform W1/O/W2 double-layer emulsion droplets. By optimizing the flow rate and ratio of the oil and water phases, a single-layer micro-droplet can be generated with a diameter range from 15.4 to 23.2 μm and remain stable for several days under normal incubation. Then the single-layer droplets were reinjected into the double emulsion generation chip. By adjusting the flow rate of drop phase, oil phase and water phase, the double-layer emulsion droplets with a diameter range from 30 to 100 μm at a rate of 1 000 droplets/s could be obtained. Escherichia coli embedded in the double-layer emulsion droplets could be cultured and induced for protein expression. This study lays a foundation for the establishment of a high-throughput screening method based on the droplet and flow cytometry.

    Reference
    Related
    Cited by
Get Citation

白立宽,袁会领,涂然,王钦宏,花尔并. 一种基于微芯片快速生成双层乳化液滴的方法[J]. Chinese Journal of Biotechnology, 2020, 36(7): 1405-1413

Copy
Related Videos

Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:November 25,2019
  • Revised:
  • Adopted:
  • Online: July 27,2020
  • Published:
Article QR Code